AB - BDI - BL

Beam Loss detectors, wire scanners and gaseous detectors for the PS complex, SPS and LHC.

 

The nAos (new Analog observation system) for the SPS  flying wire scanner is based on the Agilent Technologies E1428A 1 GSa/s VXI Oscilloscope.

Run nAos from a SPS console manager: Start Tasks/SPS Control/SPS nAos.

Because of a defect in the signal multiplexer module, do not connect more than two signals to visualize in the same time, you might find some signals not working correctly.

Installation:

BA4:

    Signals:

SA4.BWS414-PMT 1

SA4.BWS416-PMT 2

SA4.BWS414-TEMPV 4 NC

SA4.BWS416-TEMPV 5

SA4.BWS414-TFAST 7

SA4.BWS416-TFAST 8

SA4.BWS414-TEMPH 10 NC

SA4.BWS416-TEMPH 11

SA4.BWS414-THERV 13 NC

SA4.BWS416-THERV 14

SA4.BWS414-THERH 16 NC

SA4.BWS416-THERH 17

    Triggers:

SA4.BWS414-TSLOW = 1
 
SA4.BWS416-TSLOW = 2

SX4.SSC = 3

BA5:

    Signals:

SA5.BWS517-PMT 1

SA5.BWS519-PMT 2

SA5.BWS521-PMT 3

SA5.BWS517-TEMPV 4 NC

SA5.BWS519-TEMPV 5

SA5.BWS521-TEMPV 6 NC

SA5.BWS517-TFAST 7

SA5.BWS519-TFAST 8

SA5.BWS521-TFAST 9

SA5.BWS517-TEMPH 10 NC

SA5.BWS519-TEMPH 11

SA5.BWS521-TEMPH 12 NC

SA5.BWS517-THERV 13 NC

SA5.BWS519-THERV 14

SA5.BWS521-THERV 15 NC

SA5.BWS517-THERH 16 NC

SA5.BWS519-THERH 17

SA5.BWS521-THERH 18 NC

    Triggers:

SA5.BWS517-TSLOW = 1
 
SA5.BWS519-TSLOW = 2
 
SA5.BWS521-TSLOW = 3

SX5.SSC = 4

 
Number of hits: Hit Counter
Updated on 03/09/2004.